Your browser is not supported. For the best experience, a newer version or another browser is recommended.

True Indicating Steam Biological Indicat

Number of articles 34
Sort
Item no.
Display per page
Page 1 of 2
Spore Ampoules (Steam low temp) - 106 Bacillus subtillis Cell Line 350
AB5-06

Spore Ampules are SCBIs consisting of a hermetically sealed glass ampule which contains modified Tryptic Soy Broth (TSB) with a pH indicator and Geobacillus stearothermophilus Cell Line 7953 or Bacillus subtilis Cell Line 35021 (5230) Spores with a known population and resistance level. The modified TSB will transition from the initial color to yellow and or demonstrate turbidity in the presence of bacterial growth. The Spore Ampules Geobacillus stearothermophilus offer a reduced incubation period of 48 hours and 72 hours for Bacillus subtilis.

Spore Ampules are ideal for monitoring liquid steam sterilization cycles but may also utilized in dry loads. Geobacillus stearothermophilus Spore Ampules may be utilized to monitor steam processes at 121°C to 137°C, whereas Bacillus subtilis Spore Ampules are recommended for monitoring low-temperature steam processes in the range of 110°C to 118°C.

Spore Ampules are labeled for laboratory or industrial use only.

Spore Ampule - 10e4 G. stearothermophilus Cell Line 7953, Steam, 1 mL
AT-04

Spore Ampules are SCBIs consisting of a hermetically sealed glass ampule which contains modified Tryptic Soy Broth (TSB) with a pH indicator and Geobacillus stearothermophilus Cell Line 7953 or Bacillus subtilis Cell Line 35021 (5230) Spores with a known population and resistance level. The modified TSB will transition from the initial color to yellow and or demonstrate turbidity in the presence of bacterial growth. The Spore Ampules Geobacillus stearothermophilus offer a reduced incubation period of 48 hours and 72 hours for Bacillus subtilis.

Spore Ampules are ideal for monitoring liquid steam sterilization cycles but may also utilized in dry loads. Geobacillus stearothermophilus Spore Ampules may be utilized to monitor steam processes at 121°C to 137°C, whereas Bacillus subtilis Spore Ampules are recommended for monitoring low-temperature steam processes in the range of 110°C to 118°C.

Spore Ampules are labeled for laboratory or industrial use only.

Spore Ampoule - 105, 1 mL, Geobacillus stearothermophilus Cell Line 79
AT-05

Spore Ampules are SCBIs consisting of a hermetically sealed glass ampule which contains modified Tryptic Soy Broth (TSB) with a pH indicator and Geobacillus stearothermophilus Cell Line 7953 or Bacillus subtilis Cell Line 35021 (5230) Spores with a known population and resistance level. The modified TSB will transition from the initial color to yellow and or demonstrate turbidity in the presence of bacterial growth. The Spore Ampules Geobacillus stearothermophilus offer a reduced incubation period of 48 hours and 72 hours for Bacillus subtilis.

Spore Ampules are ideal for monitoring liquid steam sterilization cycles but may also utilized in dry loads. Geobacillus stearothermophilus Spore Ampules may be utilized to monitor steam processes at 121°C to 137°C, whereas Bacillus subtilis Spore Ampules are recommended for monitoring low-temperature steam processes in the range of 110°C to 118°C.

Spore Ampules are labeled for laboratory or industrial use only.

Spore Ampoule - 106, 1 mL, Geobacillus stearothermophilus Cell Line 79
AT-06

Spore Ampules are SCBIs consisting of a hermetically sealed glass ampule which contains modified Tryptic Soy Broth (TSB) with a pH indicator and Geobacillus stearothermophilus Cell Line 7953 or Bacillus subtilis Cell Line 35021 (5230) Spores with a known population and resistance level. The modified TSB will transition from the initial color to yellow and or demonstrate turbidity in the presence of bacterial growth. The Spore Ampules Geobacillus stearothermophilus offer a reduced incubation period of 48 hours and 72 hours for Bacillus subtilis.

Spore Ampules are ideal for monitoring liquid steam sterilization cycles but may also utilized in dry loads. Geobacillus stearothermophilus Spore Ampules may be utilized to monitor steam processes at 121°C to 137°C, whereas Bacillus subtilis Spore Ampules are recommended for monitoring low-temperature steam processes in the range of 110°C to 118°C.

Spore Ampules are labeled for laboratory or industrial use only.

Spore Ampule - 10e6 + NC G. stearothermophilus Cell Line 7953, Steam,
AT-0610

Spore Ampules are SCBIs consisting of a hermetically sealed glass ampule which contains modified Tryptic Soy Broth (TSB) with a pH indicator and Geobacillus stearothermophilus Cell Line 7953 or Bacillus subtilis Cell Line 35021 (5230) Spores with a known population and resistance level. The modified TSB will transition from the initial color to yellow and or demonstrate turbidity in the presence of bacterial growth. The Spore Ampules Geobacillus stearothermophilus offer a reduced incubation period of 48 hours and 72 hours for Bacillus subtilis.

Spore Ampules are ideal for monitoring liquid steam sterilization cycles but may also utilized in dry loads. Geobacillus stearothermophilus Spore Ampules may be utilized to monitor steam processes at 121°C to 137°C, whereas Bacillus subtilis Spore Ampules are recommended for monitoring low-temperature steam processes in the range of 110°C to 118°C.

Spore Ampules are labeled for laboratory or industrial use only.

Ampoule - Negative Control, 1 mL, 10/pack
AT-10-NC

AT-10-NC: Steam, 1 mL, Neg. Control Ampule, 10/Box 

  • Compliant with USP, ISO 11138-1 and ISO 11138-3 

  • Available in two sizes: 1 mL and 0.7 mL Mini Spore Ampules

  • Consistent Ampule to Ampule for Population, Purity and Resistance

  • 24 Month Shelf Life

Mini Spore Ampule - 10e5 , Steam, 0.7 mL0.7 mL
ATM-05

ATM-05 Mini Spore Ampule - 105 Steam

0.7 mL

50/Box + 10 Negative control

  • Compliant with USP, ISO 11138-1 and ISO 11138-3 

  • Available in two sizes: 1 mL and 0.7 mL Mini Spore Ampules

  • Consistent Ampule to Ampule for Population, Purity and Resistance

  • 24 Month Shelf Life

Spore Ampoule - 106, 0.7 mL, Geobacillus stearothermophilus Cell Line
ATM-06

Spore Ampules are SCBIs consisting of a hermetically sealed glass ampule which contains modified Tryptic Soy Broth (TSB) with a pH indicator and Geobacillus stearothermophilus Cell Line 7953 or Bacillus subtilis Cell Line 35021 (5230) Spores with a known population and resistance level. The modified TSB will transition from the initial color to yellow and or demonstrate turbidity in the presence of bacterial growth. The Spore Ampules Geobacillus stearothermophilus offer a reduced incubation period of 48 hours and 72 hours for Bacillus subtilis.

Spore Ampules are ideal for monitoring liquid steam sterilization cycles but may also utilized in dry loads. Geobacillus stearothermophilus Spore Ampules may be utilized to monitor steam processes at 121°C to 137°C, whereas Bacillus subtilis Spore Ampules are recommended for monitoring low-temperature steam processes in the range of 110°C to 118°C.

Spore Ampules are labeled for laboratory or industrial use only.

Spore Disc - 10e5 G. stearothermophilus Cell Line 7953, Steam, Paper
DT-05

Spore Discs DT-05 105, 6 mm Bulk, Packs of 100

Compliant with USP, ISO 11138-1 and ISO 11138-3

Spore Disc - 10e6 G. stearothermophilus Cell Line 7953, Steam, Paper
DT-06

True Indicating Steam Biological Indicators (BIs) and Inoculated Carriers are:

• Compliant with ISO 11138-1 and 11138-3

• Pure high quality Geobacillus stearothermophilus, Cell Line 7953 Spores or Bacillus subtilis Cell Line 35021 (5230) Spores for Low-Temperature Processes

• Consistent quality for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to a steam process. The Indicators may be used to monitor processes from 110°C - 137°C for equipment and process validation or routine monitoring. Use of Bacillus subtilis Spore Strips is recommended for low temperature steam sterilization processes at 110°- 118°C. The Indicators are labeled for laboratory or industrial use only.

DT-06, Population: 106, Dimensions: 6 mm, Packaging: Bulk

 

 

20 Second Indicator - 10e5, Steam, 13.5 x 52 mm
ISCS-05

20 sec Indicator 105 (STEAM)

25 Instant 20s Indiators, 1 Bottle Indiator Solution, 25 Plastic Viewing Cups, 1 Pair Disposable Tweezers

Compliant with USP, ISO 11138-1 and ISO 11138-3

Truly Advanced, Truly Instant - Results in 20 Seconds

Does not require a special reader or incubator

FDA 510k Cleared under K210481

20 Second Indicator + SCBI - 10e5, Steam, 13.5 x 52 mm
ISCS-05-BI

20 sec Indicator + SCBI 10^5 (STEAM)

25 Instant 20s Indiators, 1 Bottle Indiator Solution, 25 Plastic Viewing Cups, 1 Pair Disposable Tweezers

Compliant with USP, ISO 11138-1 and ISO 11138-3

Truly Advanced, Truly Instant - Results in 20 Seconds

Does not require a special reader or incubator

FDA 510k Cleared under K210481

20 Second Indicator - 10e6, Steam, 13.5 x 52 mm
ISCS-06

ISCS-06 20 Second Indicator 106

25 Instant 20s Indiators, 1 Bottle Indiator Solution, 25 Plastic Viewing Cups, 1 Pair Disposable Tweezers

Compliant with USP, ISO 11138-1 and ISO 11138-3

Truly Advanced, Truly Instant - Results in 20 Seconds

Does not require a special reader or incubator

FDA 510k Cleared under K210481

20 Second Indicator + SCBI - 10e6, Steam, 13.5 x 52 mm
ISCS-06-BI

ISCS-06-BI 20 Second Indicator + SCBI - 106

25 Instant 20s Indiators + SCBI, 1 Bottle Indiator Solution, 25 Plastic Viewing Cups, 1 Pair Disposable Tweezers

Compliant with USP, ISO 11138-1 and ISO 11138-3

Truly Advanced, Truly Instant - Results in 20 Seconds

Does not require a special reader or incubator

FDA 510k Cleared under K210481

Mini SCBI - 106 Geobacillus stearothermophilus Cell Line 7953 1x5cm (S
MSCST-06

True Indicating Steam SCBIs offer:

  • Compliance with ISO 11138-1 and 11138-3
  • Reduced Incubation Time of 24 Hours
  • Distinct color transition of media from Purple to Yellow when positive for Growth

The SCBIs are designed to provide assurance of effective sterilization after exposure to a steam process. The SCBIs may be used to monitor processes up to 140°C for equipment and process validations and routine monitoring. The self-sealing rigid SCBIs, SCST-05 and SCST-06, offer a better option for extended incubation up to 7 days with less concern of evaporation or color reversion of positive units.

The SCBIs are labeled for laboratory or industrial use only.

Mini Strips - 106 Geobacillus stearothermophilus Cell Line 7953 2x10mm
MT-06

True Indicating Steam Biological Indicators (BIs) and Inoculated Carriers are:

• Compliant with ISO 11138-1 and 11138-3

• Pure high quality Geobacillus stearothermophilus, Cell Line 7953 Spores or Bacillus subtilis Cell Line 35021 (5230) Spores for Low-Temperature Processes

• Consistent quality for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to a steam process. The Indicators may be used to monitor processes from 110°C - 137°C for equipment and process validation or routine monitoring. Use of Bacillus subtilis Spore Strips is recommended for low temperature steam sterilization processes at 110°- 118°C. The Indicators are labeled for laboratory or industrial use only.

Mini Spore Strips, Population: 106, Dimension: 2 mm x 10 mm, Packaging: Glassine Envelope

 

 

Mini Strips - 106 Geobacillus stearothermophilus Cell Line 7953 2x10mm
MTB-06

True Indicating Steam Biological Indicators (BIs) and Inoculated Carriers are:

• Compliant with ISO 11138-1 and 11138-3

• Pure high quality Geobacillus stearothermophilus, Cell Line 7953 Spores or Bacillus subtilis Cell Line 35021 (5230) Spores for Low-Temperature Processes

• Consistent quality for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to a steam process. The Indicators may be used to monitor processes from 110°C - 137°C for equipment and process validation or routine monitoring. Use of Bacillus subtilis Spore Strips is recommended for low temperature steam sterilization processes at 110°- 118°C. The Indicators are labeled for laboratory or industrial use only.

Mini Spore Strips, Population: 106, Dimension: 2 mm x 10 mm, Packaging: Bulk

Spore Strips - 10e5, 10e6 Dual Species G. stearothermophilus Cell Line
SAT-65

The Spore Strips are utilized to monitor Steam sterilization process efficacy at 121°C - 137°C. Spore Strips can be used for equipment and process validation and routine monitoring. The Spore Strips are labeled for laboratory/industrial use only.

Spore Strips - 10e6 Bacillus subtilis Cell Line 35021 (5230), Steam
SB5-06

True Indicating Steam Biological Indicators (BIs) and Inoculated Carriers are:

• Compliant with ISO 11138-1 and 11138-3

• Pure high quality Geobacillus stearothermophilus, Cell Line 7953 Spores or Bacillus subtilis Cell Line 35021 (5230) Spores for Low-Temperature Processes

• Consistent quality for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to a steam process. The Indicators may be used to monitor processes from 110°C - 137°C for equipment and process validation or routine monitoring. Use of Bacillus subtilis Spore Strips is recommended for low temperature steam sterilization processes at 110°- 118°C. The Indicators are labeled for laboratory or industrial use only.

Population: 106, Dimensions: 6 mm x 30 mm, Packaging: Glassine Envelope

Large SCBI - 10e5  G. stearothermophilus Cell Line 7953, Steam , 9.5 x
SCST-05

True Indicating Steam SCBIs offer:

  • Compliance with ISO 11138-1 and 11138-3
  • Reduced Incubation Time of 24 Hours
  • Distinct color transition of media from Purple to Yellow when positive for Growth

The SCBIs are designed to provide assurance of effective sterilization after exposure to a steam process. The SCBIs may be used to monitor processes up to 140°C for equipment and process validations and routine monitoring. The self-sealing rigid SCBIs, SCST-05 and SCST-06, offer a better option for extended incubation up to 7 days with less concern of evaporation or color reversion of positive units.

The SCBIs are labeled for laboratory or industrial use only.

SCBI - 106 Geobacillus stearothermophilus Cell Line 7953 (Steam) 50/bo
SCST-06

True Indicating Steam SCBIs offer:

  • Compliance with ISO 11138-1 and 11138-3
  • Reduced Incubation Time of 24 Hours
  • Distinct color transition of media from Purple to Yellow when positive for Growth

The SCBIs are designed to provide assurance of effective sterilization after exposure to a steam process. The SCBIs may be used to monitor processes up to 140°C for equipment and process validations and routine monitoring. The self-sealing rigid SCBIs, SCST-05 and SCST-06, offer a better option for extended incubation up to 7 days with less concern of evaporation or color reversion of positive units.

The SCBIs are labeled for laboratory or industrial use only.

Spore Strips - G. stearothermophilus 10x5
ST-05

True Indicating Steam Biological Indicators (BIs) and Inoculated Carriers are:

• Compliant with ISO 11138-1 and 11138-3

• Pure high quality Geobacillus stearothermophilus, Cell Line 7953 Spores or Bacillus subtilis Cell Line 35021 (5230) Spores for Low-Temperature Processes

• Consistent quality for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to a steam process. The Indicators may be used to monitor processes from 110°C - 137°C for equipment and process validation or routine monitoring. Use of Bacillus subtilis Spore Strips is recommended for low temperature steam sterilization processes at 110°- 118°C. The Indicators are labeled for laboratory or industrial use only.

Population: 105, Dimension: 6 mm x 30 mm, Packaging: Glassine Envelope

Spore Strips - 106, Geobacillus stearothermophilus Cell Line 7953, 6 x
ST-06

True Indicating Steam Biological Indicators (BIs) and Inoculated Carriers are:

• Compliant with ISO 11138-1 and 11138-3

• Pure high quality Geobacillus stearothermophilus, Cell Line 7953 Spores or Bacillus subtilis Cell Line 35021 (5230) Spores for Low-Temperature Processes

• Consistent quality for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to a steam process. The Indicators may be used to monitor processes from 110°C - 137°C for equipment and process validation or routine monitoring. Use of Bacillus subtilis Spore Strips is recommended for low temperature steam sterilization processes at 110°- 118°C. The Indicators are labeled for laboratory or industrial use only.

Population: 106, Dimension: 6 mm x 30 mm, Packaging: Glassine Envelope

Spore Thread - 10e6 G. stearothermophilus Cell Line 7953, Steam, Cotto
TT-06

True Indicating Steam Biological Indicators (BIs) and Inoculated Carriers are:

• Compliant with ISO 11138-1 and 11138-3

• Pure high quality Geobacillus stearothermophilus, Cell Line 7953 Spores or Bacillus subtilis Cell Line 35021 (5230) Spores for Low-Temperature Processes

• Consistent quality for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to a steam process. The Indicators may be used to monitor processes from 110°C - 137°C for equipment and process validation or routine monitoring. Use of Bacillus subtilis Spore Strips is recommended for low temperature steam sterilization processes at 110°- 118°C. The Indicators are labeled for laboratory or industrial use only.

TT-06, Population: 106, Dimension: 30 mm, Packaging: Glassine

 

Spore Thread - 10e6 G. stearothermophilus Cell Line 7953, Steam, Cotto
TTB-06

True Indicating Steam Biological Indicators (BIs) and Inoculated Carriers are:

• Compliant with ISO 11138-1 and 11138-3

• Pure high quality Geobacillus stearothermophilus, Cell Line 7953 Spores or Bacillus subtilis Cell Line 35021 (5230) Spores for Low-Temperature Processes

• Consistent quality for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to a steam process. The Indicators may be used to monitor processes from 110°C - 137°C for equipment and process validation or routine monitoring. Use of Bacillus subtilis Spore Strips is recommended for low temperature steam sterilization processes at 110°- 118°C. The Indicators are labeled for laboratory or industrial use only.

Population: 106, Dimension: 30 mm, Packaging: Bulk

Page 1 of 2

The product has been added to your shopping cart Show shopping cartCheckout