Your browser is not supported. For the best experience, a newer version or another browser is recommended.

TRIO.BAS Airbio Duo

Number of articles 9
Sort
Item no.
AIRBIO DUO BLUETOOTH air sampler (100 lts/min) Contact plate with Batt
TB479

Code

AIRBIO DUO CABLE

479

AIRBIO DUO 100 Contact with cable (100 litres/min flow rate)

480

AIRBIO DUO 100 Petri with cable (100 litres/min flow rate)

481

AIRBIO DUO 200 Contact with cable (200 litres/min flow rate)

482

AIRBIO DUO 200 Petri with cable (200 litres/min flow rate)

Two aspirating chambers for Petri or Contact plates with Bluetooth and cable for charging.

  • 100 or 200 l/m
  • Petri or Contact plates
  • Bluetooth or USB cable for data transfer
  • The body of the AIRBIO is designed to let the air sampler much more stable on the surface and to allow the end user to read easily the keyboard. It is also much easier to place the plates on the aspirating heads as being vertical.
  • This air sampler is especially dedicated to customers who make a large number of controls, in different environments, with a large staff rotation and comply with the quality standards and QM/GMP.
  • Main customers are pharmaceutical aseptic filling suites, cleanroom, biotech, IVF clinic, operating theatre, hospital pharmacies, blood banks, clinic, microbiological labs, HVAC building monitoring, environmental labs, healthcare ambient monitoring and health authorities.
  • The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop.
  • It is possible to work either in manual or automatic mode.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The 200 lts/min air flow reduces the operator time and the time sampling.
  • The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination and provides the certification of sterility requested by regulatory inspectors.
  • The possibility to use 2 different aspirating heads allows to have 2 different culture media at the same time or the ability to sample BEFORE (at rest), DURING (in operation) and at the END of each processing cycle.
  • The operator can program the sampling of each heads:
    • SEQUENTIAL: the second head starts sampling as soon as the first one stops or
    • SIMULTANEOUS: all heads sample at the same time
    • INTERVAL: the sampling is set at specific interval time
    • CONTINUOUS: the second and third head starts sampling as soon as the first stops
AIRBIO DUO 100 Contact KIT with Cable
TB479K

Code

AIRBIO DUO CABLE PACK (*)

479K

AIRBIO DUO 100 Contact with cable (100 litres/min flow rate)

480K

AIRBIO DUO 100 Petri with cable (100 litres/min flow rate)

481K

AIRBIO DUO 200 Contact with cable (200 litres/min flow rate)

482K

AIRBIO DUO 200 Petri with cable (200 litres/min flow rate)

(*) each PACK consists of: 1 air sampler with Bluetooth and battery charger, 1 calibration certificate, 2 s/s aspi head with s/s cover head, 1 cable for transfer data, 1 robustus carrying case.

Two aspirating chambers for Petri or Contact plates with Bluetooth and cable for charging.

  • 100 or 200 l/m
  • Petri or Contact plates
  • Bluetooth or USB cable for data transfer
  • The body of the AIRBIO is designed to let the air sampler much more stable on the surface and to allow the end user to read easily the keyboard. It is also much easier to place the plates on the aspirating heads as being vertical.
  • This air sampler is especially dedicated to customers who make a large number of controls, in different environments, with a large staff rotation and comply with the quality standards and QM/GMP.
  • Main customers are pharmaceutical aseptic filling suites, cleanroom, biotech, IVF clinic, operating theatre, hospital pharmacies, blood banks, clinic, microbiological labs, HVAC building monitoring, environmental labs, healthcare ambient monitoring and health authorities.
  • The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop.
  • It is possible to work either in manual or automatic mode.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The 200 lts/min air flow reduces the operator time and the time sampling.
  • The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination and provides the certification of sterility requested by regulatory inspectors.
  • The possibility to use 2 different aspirating heads allows to have 2 different culture media at the same time or the ability to sample BEFORE (at rest), DURING (in operation) and at the END of each processing cycle.
  • The operator can program the sampling of each heads:
    • SEQUENTIAL: the second head starts sampling as soon as the first one stops or
    • SIMULTANEOUS: all heads sample at the same time
    • INTERVAL: the sampling is set at specific interval time
    • CONTINUOUS: the second and third head starts sampling as soon as the first stops
AIRBIO DUO BLUETOOTH air sampler (100 lts/min) Petri 90 plate with Bat
TB480

Code

AIRBIO DUO CABLE

479

AIRBIO DUO 100 Contact with cable (100 litres/min flow rate)

480

AIRBIO DUO 100 Petri with cable (100 litres/min flow rate)

481

AIRBIO DUO 200 Contact with cable (200 litres/min flow rate)

482

AIRBIO DUO 200 Petri with cable (200 litres/min flow rate)


Two aspirating chambers for Petri or Contact plates with Bluetooth and cable for charging.

  • 100 or 200 l/m
  • Petri or Contact plates
  • Bluetooth or USB cable for data transfer
  • The body of the AIRBIO is designed to let the air sampler much more stable on the surface and to allow the end user to read easily the keyboard. It is also much easier to place the plates on the aspirating heads as being vertical.
  • This air sampler is especially dedicated to customers who make a large number of controls, in different environments, with a large staff rotation and comply with the quality standards and QM/GMP.
  • Main customers are pharmaceutical aseptic filling suites, cleanroom, biotech, IVF clinic, operating theatre, hospital pharmacies, blood banks, clinic, microbiological labs, HVAC building monitoring, environmental labs, healthcare ambient monitoring and health authorities.
  • The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop.
  • It is possible to work either in manual or automatic mode.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The 200 lts/min air flow reduces the operator time and the time sampling.
  • The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination and provides the certification of sterility requested by regulatory inspectors.
  • The possibility to use 2 different aspirating heads allows to have 2 different culture media at the same time or the ability to sample BEFORE (at rest), DURING (in operation) and at the END of each processing cycle.
  • The operator can program the sampling of each heads:
    • SEQUENTIAL: the second head starts sampling as soon as the first one stops or
    • SIMULTANEOUS: all heads sample at the same time
    • INTERVAL: the sampling is set at specific interval time
    • CONTINUOUS: the second and third head starts sampling as soon as the first stops
AIRBIO DUO 100 Petri KIT with Cable
TB480K

Code

AIRBIO DUO CABLE PACK (*)

479K

AIRBIO DUO 100 Contact with cable (100 litres/min flow rate)

480K

AIRBIO DUO 100 Petri with cable (100 litres/min flow rate)

481K

AIRBIO DUO 200 Contact with cable (200 litres/min flow rate)

482K

AIRBIO DUO 200 Petri with cable (200 litres/min flow rate)

(*) each PACK consists of: 1 air sampler with Bluetooth and battery charger, 1 calibration certificate, 2 s/s aspi head with s/s cover head, 1 cable for transfer data, 1 robustus carrying case.

Two aspirating chambers for Petri or Contact plates with Bluetooth and cable for charging.

  • 100 or 200 l/m
  • Petri or Contact plates
  • Bluetooth or USB cable for data transfer
  • The body of the AIRBIO is designed to let the air sampler much more stable on the surface and to allow the end user to read easily the keyboard. It is also much easier to place the plates on the aspirating heads as being vertical.
  • This air sampler is especially dedicated to customers who make a large number of controls, in different environments, with a large staff rotation and comply with the quality standards and QM/GMP.
  • Main customers are pharmaceutical aseptic filling suites, cleanroom, biotech, IVF clinic, operating theatre, hospital pharmacies, blood banks, clinic, microbiological labs, HVAC building monitoring, environmental labs, healthcare ambient monitoring and health authorities.
  • The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop.
  • It is possible to work either in manual or automatic mode.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The 200 lts/min air flow reduces the operator time and the time sampling.
  • The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination and provides the certification of sterility requested by regulatory inspectors.
  • The possibility to use 2 different aspirating heads allows to have 2 different culture media at the same time or the ability to sample BEFORE (at rest), DURING (in operation) and at the END of each processing cycle.
  • The operator can program the sampling of each heads:
    • SEQUENTIAL: the second head starts sampling as soon as the first one stops or
    • SIMULTANEOUS: all heads sample at the same time
    • INTERVAL: the sampling is set at specific interval time
    • CONTINUOUS: the second and third head starts sampling as soon as the first stops
AIRBIO DUO BLUETOOTH air sampler (200 lts/min) Contact plate with Batt
TB481

Code

AIRBIO DUO CABLE

479

AIRBIO DUO 100 Contact with cable (100 litres/min flow rate)

480

AIRBIO DUO 100 Petri with cable (100 litres/min flow rate)

481

AIRBIO DUO 200 Contact with cable (200 litres/min flow rate)

482

AIRBIO DUO 200 Petri with cable (200 litres/min flow rate)

 

Two aspirating chambers for Petri or Contact plates with Bluetooth and cable for charging.

  • 100 or 200 l/m
  • Petri or Contact plates
  • Bluetooth or USB cable for data transfer
  • The body of the AIRBIO is designed to let the air sampler much more stable on the surface and to allow the end user to read easily the keyboard. It is also much easier to place the plates on the aspirating heads as being vertical.
  • This air sampler is especially dedicated to customers who make a large number of controls, in different environments, with a large staff rotation and comply with the quality standards and QM/GMP.
  • Main customers are pharmaceutical aseptic filling suites, cleanroom, biotech, IVF clinic, operating theatre, hospital pharmacies, blood banks, clinic, microbiological labs, HVAC building monitoring, environmental labs, healthcare ambient monitoring and health authorities.
  • The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop.
  • It is possible to work either in manual or automatic mode.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The 200 lts/min air flow reduces the operator time and the time sampling.
  • The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination and provides the certification of sterility requested by regulatory inspectors.
  • The possibility to use 2 different aspirating heads allows to have 2 different culture media at the same time or the ability to sample BEFORE (at rest), DURING (in operation) and at the END of each processing cycle.
  • The operator can program the sampling of each heads:
    • SEQUENTIAL: the second head starts sampling as soon as the first one stops or
    • SIMULTANEOUS: all heads sample at the same time
    • INTERVAL: the sampling is set at specific interval time
    • CONTINUOUS: the second and third head starts sampling as soon as the first stops
AIRBIO DUO 200 Contact KIT with Cable
TB481K

Code

AIRBIO DUO CABLE PACK (*)

479K

AIRBIO DUO 100 Contact with cable (100 litres/min flow rate)

480K

AIRBIO DUO 100 Petri with cable (100 litres/min flow rate)

481K

AIRBIO DUO 200 Contact with cable (200 litres/min flow rate)

482K

AIRBIO DUO 200 Petri with cable (200 litres/min flow rate)

(*) each PACK consists of: 1 air sampler with Bluetooth and battery charger, 1 calibration certificate, 2 s/s aspi head with s/s cover head, 1 cable for transfer data, 1 robustus carrying case.

Two aspirating chambers for Petri or Contact plates with Bluetooth and cable for charging.

  • 100 or 200 l/m
  • Petri or Contact plates
  • Bluetooth or USB cable for data transfer
  • The body of the AIRBIO is designed to let the air sampler much more stable on the surface and to allow the end user to read easily the keyboard. It is also much easier to place the plates on the aspirating heads as being vertical.
  • This air sampler is especially dedicated to customers who make a large number of controls, in different environments, with a large staff rotation and comply with the quality standards and QM/GMP.
  • Main customers are pharmaceutical aseptic filling suites, cleanroom, biotech, IVF clinic, operating theatre, hospital pharmacies, blood banks, clinic, microbiological labs, HVAC building monitoring, environmental labs, healthcare ambient monitoring and health authorities.
  • The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop.
  • It is possible to work either in manual or automatic mode.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The 200 lts/min air flow reduces the operator time and the time sampling.
  • The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination and provides the certification of sterility requested by regulatory inspectors.
  • The possibility to use 2 different aspirating heads allows to have 2 different culture media at the same time or the ability to sample BEFORE (at rest), DURING (in operation) and at the END of each processing cycle.
  • The operator can program the sampling of each heads:
    • SEQUENTIAL: the second head starts sampling as soon as the first one stops or
    • SIMULTANEOUS: all heads sample at the same time
    • INTERVAL: the sampling is set at specific interval time
    • CONTINUOUS: the second and third head starts sampling as soon as the first stops
AIRBIO DUO BLUETOOTH air sampler (200 lts/min) Petri 90 plate with Bat
TB482

Code

AIRBIO DUO CABLE

479

AIRBIO DUO 100 Contact with cable (100 litres/min flow rate)

480

AIRBIO DUO 100 Petri with cable (100 litres/min flow rate)

481

AIRBIO DUO 200 Contact with cable (200 litres/min flow rate)

482

AIRBIO DUO 200 Petri with cable (200 litres/min flow rate)

 

Two aspirating chambers for Petri or Contact plates with Bluetooth and cable for charging.

  • 100 or 200 l/m
  • Petri or Contact plates
  • Bluetooth or USB cable for data transfer
  • The body of the AIRBIO is designed to let the air sampler much more stable on the surface and to allow the end user to read easily the keyboard. It is also much easier to place the plates on the aspirating heads as being vertical.
  • This air sampler is especially dedicated to customers who make a large number of controls, in different environments, with a large staff rotation and comply with the quality standards and QM/GMP.
  • Main customers are pharmaceutical aseptic filling suites, cleanroom, biotech, IVF clinic, operating theatre, hospital pharmacies, blood banks, clinic, microbiological labs, HVAC building monitoring, environmental labs, healthcare ambient monitoring and health authorities.
  • The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop.
  • It is possible to work either in manual or automatic mode.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The 200 lts/min air flow reduces the operator time and the time sampling.
  • The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination and provides the certification of sterility requested by regulatory inspectors.
  • The possibility to use 2 different aspirating heads allows to have 2 different culture media at the same time or the ability to sample BEFORE (at rest), DURING (in operation) and at the END of each processing cycle.
  • The operator can program the sampling of each heads:
    • SEQUENTIAL: the second head starts sampling as soon as the first one stops or
    • SIMULTANEOUS: all heads sample at the same time
    • INTERVAL: the sampling is set at specific interval time
    • CONTINUOUS: the second and third head starts sampling as soon as the first stops
AIRBIO DUO 200 Petri KIT with Cable
TB482K

Code

AIRBIO DUO CABLE PACK (*)

479K

AIRBIO DUO 100 Contact with cable (100 litres/min flow rate)

480K

AIRBIO DUO 100 Petri with cable (100 litres/min flow rate)

481K

AIRBIO DUO 200 Contact with cable (200 litres/min flow rate)

482K

AIRBIO DUO 200 Petri with cable (200 litres/min flow rate)

(*) each PACK consists of: 1 air sampler with Bluetooth and battery charger, 1 calibration certificate, 2 s/s aspi head with s/s cover head, 1 cable for transfer data, 1 robustus carrying case.

Two aspirating chambers for Petri or Contact plates with Bluetooth and cable for charging.

  • 100 or 200 l/m
  • Petri or Contact plates
  • Bluetooth or USB cable for data transfer
  • The body of the AIRBIO is designed to let the air sampler much more stable on the surface and to allow the end user to read easily the keyboard. It is also much easier to place the plates on the aspirating heads as being vertical.
  • This air sampler is especially dedicated to customers who make a large number of controls, in different environments, with a large staff rotation and comply with the quality standards and QM/GMP.
  • Main customers are pharmaceutical aseptic filling suites, cleanroom, biotech, IVF clinic, operating theatre, hospital pharmacies, blood banks, clinic, microbiological labs, HVAC building monitoring, environmental labs, healthcare ambient monitoring and health authorities.
  • The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop.
  • It is possible to work either in manual or automatic mode.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The 200 lts/min air flow reduces the operator time and the time sampling.
  • The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination and provides the certification of sterility requested by regulatory inspectors.
  • The possibility to use 2 different aspirating heads allows to have 2 different culture media at the same time or the ability to sample BEFORE (at rest), DURING (in operation) and at the END of each processing cycle.
  • The operator can program the sampling of each heads:
    • SEQUENTIAL: the second head starts sampling as soon as the first one stops or
    • SIMULTANEOUS: all heads sample at the same time
    • INTERVAL: the sampling is set at specific interval time
    • CONTINUOUS: the second and third head starts sampling as soon as the first stops
AIRBIO DUO CM 25 l/m PETRI with cable KIT
TB854K

Airbio One for continuous monitoring

854K AIRBIO DUO CM 25 l/m PETRI with cable PACK (25 litres/min flow rate) (*)

(*) each PACK consists of: 1 air sampler with Bluetooth and battery charger, 1 calibration certificate, 2 s/s aspirating head (code 830) with s/s cover head (code 465), 1 cable for transfer data and 1 robustus carrying case.

Airbio One for continous monitoring

853K                   AIRBIO ONE CM 25 l/m PETRI with cable PACK (25 litres/min flow rate) (*)

(*) each PACK consists of: 1 air sampler with Bluetooth and battery charger, 1 calibration certificate, 1 s/s aspirating head (code 830) with s/s cover head (code 465), 1 cable for transfer data and 1 robustus carrying case.

The GMP Annex 1 introduced news about the microbial air monitoring in Grade “A” and “B” of the cleanroom:

The paragraphs 9.22 and 9.24 of the Chapter 9 say:

9.22 Where aseptic operations are performed, microbial monitoring should be frequent using a combination of methods such as settle plates, volumetric air sampling, glove, gown and surface sampling (e.g. swabs and contact plates). The method of sampling used should @e justified within the CCS and should be demonstrated not to have a detrimental impact on grade A and B airflow patterns. Cleanroom and equipment surfaces should be monitored at the end of an operation.

9.24 Continuous viable air monitoring in grade A (e.g. air sampling or settle plates) should be undertaken for the full duration of critical processing, including equipment (aseptic set-up) assembly and critical processing. A similar approach should be considered for grade B cleanrooms based on the risk of impact on the aseptic processing. The monitoring should be performed in such a way that all interventions, transient events and any system deterioration would be captured and any risk caused by interventions of the monitoring operations is avoided.

The new generation of ORUM microbial air samplers called "CM" have been developed to follow these new indications of GMP Annex 1.

The product has been added to your shopping cart Show shopping cartCheckout