Your browser is not supported. For the best experience, a newer version or another browser is recommended.

True Indicating EO Biological Indicators

Number of articles 18
Sort
Item no.
Spore Disc - 106 Bacillus atrophaeus Cell Line 9372, EO, Paper
DA-06

True Indicating EO Biological Indicators are:

  • Compliant with ISO 11138-1 and 11138-2
  • Pure high quality Bacillus atrophaeus spores, Cell Line 9372 in Water For Injection (WFI) only
  • Consistent in quality Indicator to Indicator for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring.

The Indicators are labeled for laboratory/industrial use only.

106/disc, 6 mm, Bulk

Mini Spore Strips - 10e6 Bacillus atrophaeus Cell Line 9372, EO
MA-06

True Indicating EO Biological Indicators are:

  • Compliant with ISO 11138-1 and 11138-2
  • Pure high quality Bacillus atrophaeus spores, Cell Line 9372 in Water For Injection (WFI) only
  • Consistent in quality Indicator to Indicator for Population, Purity and Resistance The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring. The Indicators are labeled for laboratory/industrial use only. True Indicating offers standard configurations of Biological Indicator and Inoculated Carriers; see table below. In addition to standard configurations, True Indicating will manufacture Custom Indicators to meet your needs.

106/strip, 2 mm x 10 mm, Glassine Envelope

 

 

Mini Spore Strips - 10e6 Bacillus atrophaeus Cell Line 9372, EO
MAB-06

True Indicating EO Biological Indicators are:

  • Compliant with ISO 11138-1 and 11138-2
  • Pure high quality Bacillus atrophaeus spores, Cell Line 9372 in Water For Injection (WFI) only
  • Consistent in quality Indicator to Indicator for Population, Purity and Resistance The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring. The Indicators are labeled for laboratory/industrial use only. True Indicating offers standard configurations of Biological Indicator and Inoculated Carriers; see table below. In addition to standard configurations, True Indicating will manufacture Custom Indicators to meet your needs.

106/strip, 2 mm x 10 mm, Bulk

EZTest EO - Gas  B. atrophaeus 10x6
MSCEA-06

True Indicating EO SCBIs offer:

• Compliance with ISO 11138-1 and 11138-2

• Reduced Incubation Time of 48 Hours

• Distinct color transition of media from Green to Yellow when Positive for Growth

The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring. The self-sealing design of the Rigid SCBIs, SCEA-06, offer a better option for extended incubation up to 7 days without concern of evaporation or color reversion of positive units.

The Indicators are labeled for laboratory/industrial use only.

106/SCBI, 8.3 mm x 46 mm, 100/Box

 

 

Mini SCBI - 105 Geobacillus stearothermophilus Cell Line 7953 1x5cm (S
MSCST-05

True Indicating Steam SCBIs offer:

  • Compliance with ISO 11138-1 and 11138-3
  • Reduced Incubation Time of 24 Hours
  • Distinct color transition of media from Purple to Yellow when positive for Growth

The SCBIs are designed to provide assurance of effective sterilization after exposure to a steam process. The SCBIs may be used to monitor processes up to 140°C for equipment and process validations and routine monitoring. The self-sealing rigid SCBIs, SCST-05 and SCST-06, offer a better option for extended incubation up to 7 days with less concern of evaporation or color reversion of positive units.

The SCBIs are labeled for laboratory or industrial use only.

Mini Spore Wire - 10e6 Bacillus atrophaeus Cell Line 9372, EO, Steel
MWAB-06

Mini Spore Wire - 106

EO Steel Bulk 100/pk

MWAB-06 38 × 0.3 mm

Spore Strips B. atrophaeus 106
SA-06

ETHYLENE OXIDE (EO) SPORE STRIPS SA-06

Bacillus atrophaeus, Cell Line 3972

SA-06

10^6

6 mm x 30 mm

Glassine Envelopes

Compliant with USP, ISO 11138-1 and ISO 11138-3

Large SCBI - 10e6 Bacillus atrophaeus Cell Line 9372, EO, 9.5 x 48 mm
SCEA-06

Self-Contained Biological Indicator

True Indicating EO SCBIs offer:

  • Compliance with ISO 11138-1 and 11138-2
  • Reduced Incubation Time of 48 Hours
  • Distinct color transition of media from Green to Yellow when Positive for Growth

The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring. The self-sealing design of the Rigid SCBIs, SCEA-06, offer a better option for extended incubation up to 7 days without concern of evaporation or color reversion of positive units.

The Indicators are labeled for laboratory/industrial use only.

106/SCBI, 9.5 mm x 48 mm, 50/Box

Spore Thread - 10e6 Bacillus atrophaeus Cell Line 9372, EO, Cotton Thr
TA-06

True Indicating EO Biological Indicators are:

  • Compliant with ISO 11138-1 and 11138-2
  • Pure high quality Bacillus atrophaeus spores, Cell Line 9372 in Water For Injection (WFI) only
  • Consistent in quality Indicator to Indicator for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring.

The Indicators are labeled for laboratory/industrial use only.

106/thread, 30 mm,Glassine Envelope

 

 

 

 

 

Spore Thread - 10e6 Bacillus atrophaeus Cell Line 9372, EO, Cotton Thr
TAB-06

True Indicating EO Biological Indicators are:

  • Compliant with ISO 11138-1 and 11138-2
  • Pure high quality Bacillus atrophaeus spores, Cell Line 9372 in Water For Injection (WFI) only
  • Consistent in quality Indicator to Indicator for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring.

The Indicators are labeled for laboratory/industrial use only.

106/thread, 30 mm, Bulk

Spore Suspension - 102/0.1mL Bacillus atrophaeus Cell Line 9372 (EO/Dr
UA-02

ETHYLENE OXIDE (EO) SPORE SUSPENSIONS

102/0.1mL

10 mL/vial

True Indicating Spore Suspensions are pure suspensions of spores suspended in Water for Injection.​

  • Each 10 mL vial has a standardized population per 0.1 mL 

  • Spore Suspensions are packaged in pharmaceutical vials with caps and septum to allow access via a pipet or syringe

  • Shipment on ice and refrigerated storage required

Spore Suspension - 106/0.1mL Bacillus atrophaeus Cell Line 9372 (EO/Dr
UA-06

True Indicating Spore Suspensions are:

  • Compliant with ISO 11138-1, 11138-2 and USP
  • Packaged in pharmaceutical vials with caps and septum allow access via a pipette or syringe
  • Pure suspensions of Bacillus atrophaeus, Cell Line 9372 suspended in Water For Injection (WFI)

The Spore Suspensions are designed for use in direct inoculation or other studies where assurance of effective sterilization after exposure to an EO process is required. Custom population levels and other diluents including Ethanol available upon request.

106/0.1 mL, Volume: 10 mL, Shelf life: 36 Months

 

 

 

Spore Suspension - 107/0.1mL Bacillus atrophaeus Cell Line 9372 (EO/Dr
UA-07

True Indicating Spore Suspensions are:

  • Compliant with ISO 11138-1, 11138-2 and USP
  • Packaged in pharmaceutical vials with caps and septum allow access via a pipette or syringe
  • Pure suspensions of Bacillus atrophaeus, Cell Line 9372 suspended in Water For Injection (WFI)

The Spore Suspensions are designed for use in direct inoculation or other studies where assurance of effective sterilization after exposure to an EO process is required. Custom population levels and other diluents including Ethanol available upon request.

107/0.1 mL, Volume: 10 mL, Shelf life: 36 Months

Spore Suspension - 108/0.1mL Bacillus atrophaeus Cell Line 9372 (EO/Dr
UA-08

True Indicating Spore Suspensions are:

  • Compliant with ISO 11138-1, 11138-2 and USP
  • Packaged in pharmaceutical vials with caps and septum allow access via a pipette or syringe
  • Pure suspensions of Bacillus atrophaeus, Cell Line 9372 suspended in Water For Injection (WFI)

The Spore Suspensions are designed for use in direct inoculation or other studies where assurance of effective sterilization after exposure to an EO process is required. Custom population levels and other diluents including Ethanol available upon request.

108/0.1 mL, Volume: 10 mL, Shelf life: 36 Months

Spore Suspension - 109.1mL Bacillus atrophaeus Cell Line 9372 (EO/Dr
UA-09

ETHYLENE OXIDE (EO) SPORE SUSPENSIONS

109/0.1mL

10 mL/vial

True Indicating Spore Suspensions are pure suspensions of spores suspended in Water for Injection.​

  • Each 10 mL vial has a standardized population per 0.1 mL 
  • Spore Suspensions are packaged in pharmaceutical vials with caps and septum to allow access via a pipet or syringe
  • Shipment on ice and refrigerated storage required
Spore Wire - 10e6 Bacillus atrophaeus Cell Line 9372, EO, Steel
WA-06

True Indicating EO Biological Indicators are:

  • Compliant with ISO 11138-1 and 11138-2
  • Pure high quality Bacillus atrophaeus spores, Cell Line 9372 in Water For Injection (WFI) only
  • Consistent in quality Indicator to Indicator for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring.

The Indicators are labeled for laboratory/industrial use only.

106/wire, 38 x 1.5 mm, Glassine Envelope

 

 

Spore Wire - 10e6 Bacillus atrophaeus Cell Line 9372, EO, Steel
WAB-06

True Indicating EO Biological Indicators are:

  • Compliant with ISO 11138-1 and 11138-2
  • Pure high quality Bacillus atrophaeus spores, Cell Line 9372 in Water For Injection (WFI) only
  • Consistent in quality Indicator to Indicator for Population, Purity and Resistance

The Indicators are designed to provide assurance of effective sterilization after exposure to an EO process. The Indicators may be used to monitor processes with 100% or EO gas mixtures for equipment and process validation or routine monitoring.

The Indicators are labeled for laboratory/industrial use only.

106/wire, 38 x 1.5 mm, Bulk

The product has been added to your shopping cart Show shopping cartCheckout